DryLine Structural Sheathing
Grades
| Grade | Nominal thickness | Weight per 4′ x 8′ sheet | TER | Application |
|---|---|---|---|---|
| Green | 0.078″ | 9 lb | 1310-04 | Light bracing demand, thinnest profile |
| Red | 0.105″ | 12 lb | 1310-01 | Highest shear capacity with GWB |
| Black | 0.115″ | 14 lb | 1310-05 | Shortest required braced wall length |
| Blue | 0.137″ | 16 lb | 1310-03 | 24″ o.c. stud spacing, highest uplift |
Thicknesses are nominal. Use the current evaluation report for design values.
Physical and Structural Properties
Values are from the current DrJ Technical Evaluation Reports.
| Property | Green | Red | Black | Blue | Test standard |
|---|---|---|---|---|---|
| Water vapor permeance | < 0.6 perm | < 0.3 perm | < 0.3 perm | < 0.3 perm | ASTM E96 |
| Vapor retarder class | Class II | Class II | Class II | Class II | |
| Air permeance | < 0.02 L/(s·m²) | < 0.02 | < 0.02 | < 0.02 | ASTM E2178 |
| Basic wind speed, Vult | 200 mph | 200 mph | 200 mph | 200 mph | |
| Allowable stress design, Vasd | 155 mph | 155 mph | 155 mph | 155 mph | |
| Transverse wind pressure | 135 psf | 120 psf | 120 psf | 100 psf | ASTM E330 |
| Stud spacing for transverse value | 16″ o.c. | 16″ o.c. | 16″ o.c. | 24″ o.c. | |
| Allowable unit shear, 1/2″ GWB at 4:16 | 425 plf | 560 plf | 515 plf | 525 plf | ASTM E2126 |
| Allowable unit shear, no GWB | 200 plf | 310 plf | 285 plf | 385 plf | ASTM E2126 |
| WSP bracing equivalency factor | 0.99 | 0.87 | 0.83 | 0.93 | ASTM D7989 |
A lower equivalency factor requires less braced wall length relative to Method WSP. Shear values are the maximum tabulated for each grade; additional fastening patterns and joint treatments are tabulated in each report.
Transverse resistance is governed by panel bending and fastener pull-through rather than thickness alone, which is why the Green value is not ordered by caliper. Each value is as tested and reported in that grade’s report.
Wall Assembly Comparison
| With OSB or ZIP System | With DryLine TSX | |
|---|---|---|
| Sheathing thickness | 0.438″ | 0.105″ |
| Total wall assembly thickness | 0.94″ to 1.18″ | 0.605″ to 0.855″ |
The thinner assembly matters most where exterior continuous insulation is specified and window and trim details are already tight. A 7/16″ OSB panel weighs approximately 45 lb per 4′ x 8′ sheet against 9 to 16 lb for DryLine. DryLine also carries a factory-applied water-resistive barrier, eliminating a separate housewrap layer when joints are lapped 3/4″ or taped to the report.
Installation Requirements
WRB and air barrier recognition apply only when the board is installed as the report specifies.
- Seams and lapped joints overlap 3/4″ or are covered with minimum 1-1/2″ DryLine Sheathing Tape or equivalent
- Butt joints sealed with the same tape
- Flashing installed at all sheathing penetrations
- Structural fastening with minimum 15/16″ crown x 1-1/4″ leg 16-gauge galvanized staples or 0.120″ x 1-1/4″ galvanized roofing nails
- Fastener spacing 3″ o.c. at edges and in the field, minimum 3/8″ edge distance
Draftstop is a separate application under TER 1303-07 and TER 2205-01. DryLine installed over another manufacturer’s foam is Brace-Plate under TER 1608-04. Fibre Converters manufactures the sheathing. Continuous insulation, tapes, and flashing are specified separately, and we do not publish R-values for foam we do not make.
Permit Submittals
Section 12 of each evaluation report requires the report and the installation instructions to be submitted together at permit application. Section 9 requires a copy of the installation instructions on the jobsite during installation. Contact us for the current installation instructions for your grade.
Where the installation instructions and the evaluation report conflict, section 9.2 directs the installer to contact the manufacturer. Call (269) 279-1700.
Sizes
Standard widths 48″ and 48-3/4″. Standard lengths 96″, 108″, and 120″. Other sizes available by request. Custom printing available.
Sustainability
Manufactured in the USA from 98 percent recycled material with no added formaldehyde. Contributes to LEED points. Contact us for help applying DryLine to sustainable building rating systems on a specific project.
Warranty and Quality
Fibre Converters warrants DryLine TSX against manufacturing defects for 30 years on product manufactured on or after January 1, 2025. Fibre Converters is ISO 9001:2015 certified. Both documents are on our Key Documents page.
Where to Buy
National Shelter Products is the exclusive sales representative for DryLine. Contact them for pricing, availability, distribution, custom printing, and builder volume incentive programs.
For technical questions, specification support, or anything covered by the evaluation reports, contact Fibre Converters at (269) 279-1700.
Evaluation Reports
Fibre Converters, Inc. is the report holder on all DryLine evaluation reports.
Green
TER 1310-04, DryLine Green Structural Sheathing
Red
TER 1310-01, DryLine Red Structural Sheathing
Black
TER 1310-05, DryLine Black Structural Sheathing
Blue
TER 1310-03, DryLine Blue Structural Sheathing
All grades
TER 1303-07, DryLine Sheathing for Use as Draftstops
TER 2205-01, DryLine Nonstructural Sheathing for Use as Draftstops
Full index on Qualtim
Request a Quote
Send us:
- Braced wall requirement or shear demand
- Stud spacing
- Sheet width and length
- Whether the board carries WRB and air barrier duty
- Whether continuous insulation is going over it
- Annual volume
- Custom printing requirements