DryLine Structural Sheathing

Grades

GradeNominal thicknessWeight per 4′ x 8′ sheetTERApplication
Green0.078″9 lb1310-04Light bracing demand, thinnest profile
Red0.105″12 lb1310-01Highest shear capacity with GWB
Black0.115″14 lb1310-05Shortest required braced wall length
Blue0.137″16 lb1310-0324″ o.c. stud spacing, highest uplift

Thicknesses are nominal. Use the current evaluation report for design values.

Physical and Structural Properties

Values are from the current DrJ Technical Evaluation Reports.

PropertyGreenRedBlackBlueTest standard
Water vapor permeance< 0.6 perm< 0.3 perm< 0.3 perm< 0.3 permASTM E96
Vapor retarder classClass IIClass IIClass IIClass II
Air permeance< 0.02 L/(s·m²)< 0.02< 0.02< 0.02ASTM E2178
Basic wind speed, Vult200 mph200 mph200 mph200 mph
Allowable stress design, Vasd155 mph155 mph155 mph155 mph
Transverse wind pressure135 psf120 psf120 psf100 psfASTM E330
Stud spacing for transverse value16″ o.c.16″ o.c.16″ o.c.24″ o.c.
Allowable unit shear, 1/2″ GWB at 4:16425 plf560 plf515 plf525 plfASTM E2126
Allowable unit shear, no GWB200 plf310 plf285 plf385 plfASTM E2126
WSP bracing equivalency factor0.990.870.830.93ASTM D7989

A lower equivalency factor requires less braced wall length relative to Method WSP. Shear values are the maximum tabulated for each grade; additional fastening patterns and joint treatments are tabulated in each report.

Transverse resistance is governed by panel bending and fastener pull-through rather than thickness alone, which is why the Green value is not ordered by caliper. Each value is as tested and reported in that grade’s report.

Wall Assembly Comparison

With OSB or ZIP SystemWith DryLine TSX
Sheathing thickness0.438″0.105″
Total wall assembly thickness0.94″ to 1.18″0.605″ to 0.855″

The thinner assembly matters most where exterior continuous insulation is specified and window and trim details are already tight. A 7/16″ OSB panel weighs approximately 45 lb per 4′ x 8′ sheet against 9 to 16 lb for DryLine. DryLine also carries a factory-applied water-resistive barrier, eliminating a separate housewrap layer when joints are lapped 3/4″ or taped to the report.

Installation Requirements

WRB and air barrier recognition apply only when the board is installed as the report specifies.

  • Seams and lapped joints overlap 3/4″ or are covered with minimum 1-1/2″ DryLine Sheathing Tape or equivalent
  • Butt joints sealed with the same tape
  • Flashing installed at all sheathing penetrations
  • Structural fastening with minimum 15/16″ crown x 1-1/4″ leg 16-gauge galvanized staples or 0.120″ x 1-1/4″ galvanized roofing nails
  • Fastener spacing 3″ o.c. at edges and in the field, minimum 3/8″ edge distance

Draftstop is a separate application under TER 1303-07 and TER 2205-01. DryLine installed over another manufacturer’s foam is Brace-Plate under TER 1608-04. Fibre Converters manufactures the sheathing. Continuous insulation, tapes, and flashing are specified separately, and we do not publish R-values for foam we do not make.

Permit Submittals

Section 12 of each evaluation report requires the report and the installation instructions to be submitted together at permit application. Section 9 requires a copy of the installation instructions on the jobsite during installation. Contact us for the current installation instructions for your grade.

Where the installation instructions and the evaluation report conflict, section 9.2 directs the installer to contact the manufacturer. Call (269) 279-1700.

Sizes

Standard widths 48″ and 48-3/4″. Standard lengths 96″, 108″, and 120″. Other sizes available by request. Custom printing available.

Sustainability

Manufactured in the USA from 98 percent recycled material with no added formaldehyde. Contributes to LEED points. Contact us for help applying DryLine to sustainable building rating systems on a specific project.

Warranty and Quality

Fibre Converters warrants DryLine TSX against manufacturing defects for 30 years on product manufactured on or after January 1, 2025. Fibre Converters is ISO 9001:2015 certified. Both documents are on our Key Documents page.

Where to Buy

National Shelter Products is the exclusive sales representative for DryLine. Contact them for pricing, availability, distribution, custom printing, and builder volume incentive programs.

For technical questions, specification support, or anything covered by the evaluation reports, contact Fibre Converters at (269) 279-1700.

Evaluation Reports

Fibre Converters, Inc. is the report holder on all DryLine evaluation reports.

Green

TER 1310-04, DryLine Green Structural Sheathing

Red

TER 1310-01, DryLine Red Structural Sheathing

Black

TER 1310-05, DryLine Black Structural Sheathing

Blue

TER 1310-03, DryLine Blue Structural Sheathing

All grades

TER 1303-07, DryLine Sheathing for Use as Draftstops

TER 2205-01, DryLine Nonstructural Sheathing for Use as Draftstops

TER 1608-04, Brace-Plate

Full index on Qualtim

Request a Quote

Send us:

  • Braced wall requirement or shear demand
  • Stud spacing
  • Sheet width and length
  • Whether the board carries WRB and air barrier duty
  • Whether continuous insulation is going over it
  • Annual volume
  • Custom printing requirements

Request a quote.

DRYline is a registered trademark of National Shelter Products, Inc.

What can Fibre Converters do for you?

Our friendly and helpful Specialists can talk through your project and needs with you.